Search
Call for Live Order Assistance & Technical Support (7:30am-5pm CST)
All Categories
    Menu Close
    RSS

    Blog

    What Kind of Pump Do I Need for DEF? 

    Selective catalytic reduction is an advanced process that is intended to minimize pollution from diesel engines and contribute to better air quality. Diesel exhaust fluid, or DEF, is central to this process.

    If you use modern farm or construction equipment you are well aware of the regulations that require the use of DEF. Although DEF is a simple liquid, consisting of urea and water, it does have unique properties. So for those who need to fuel equipment, the question arises what kind of pump do I need for DEF?

    In this guide, Will will be looking at the properties of DEF to understand what types of materials are compatible with it. We will also take a look at the different DEF pump options and accessories.

     

    Understanding What Pump Types Are Suitable for DEF

    The most important thing to consider when selecting a pump for DEF is material compatibility. There are other factors to consider such as flow rate and drive type, but this is most important. Let's look at the materials that work for pumping DEF and the types of pumps that will work.

     

    Material Compatibility

    Diesel Exhaust Fluid (DEF) is a solution made up of 32.5% urea and 67.5% deionized water. DEF is non-toxic, non-flammable, and non-hazardous under normal conditions. However, DEF is not compatible with most metals and some plastics. This limits the pumps that are suitable to be used with it.

    How important is this really? What is the worst that can happen if you use just any old pump? Simply put, it may work for a very short period but it won't be long before you have issues. DEF decomposes into ammonia, which corrodes incompatible metals like copper, zinc, and aluminum. It causes pitting, erosion, oxidation, and galvanic corrosion, weakening metal and leading to rapid component damage.

    So what materials do work with DEF? Stainless steel (grades 304 and 316), polyethylene, and polypropylene are resistant to the effects of DEF. Therefore manufacturers use these materials to construct pumps suitable for DEF. The seals and gaskets used for DEF pumps are EPDM or Viton.

     

    Material suitable for handling DEF:

    • Polypropylene
    • Viton
    • EPDM
    • Stainless Steel

     

    Blog Heading

     

    Pump Types for DEF

    Although the materials suited for DEF are limited, there are several different types of pump that will work fine for DEF fluid. Centrifugal pumps, diaphragm pumps, gear pumps, and even submersible pumps. Again, the type is not as important as the materials and elastomers used to construct the pump.

    Centrifugal pumps are most common for large volumes, and diaphragm pumps are used for dispensing into vehicles and equipment. Diaphragm pumps for DEF will generally come as a kit that includes the hoses, nozzles, and couplings needed for DEF barrels or other pre-packaged containers (more about this in a moment). 

    • Centrifugal Pumps
    • Diaphragm Pumps
    • Submersible Pump

     

    Pump Drive Types for DEF

    A variety of drive options can be used for DEF Pumps. Electric motors, gas engines, hydraulic motors, air-driven pumps, and more. No matter what kind of power supply, you can find a pump that will work for you.

    • Electric
    • Gas-engine Driven
    • Air Operated

     

    DEF Pump Couplings

    Many DEF tanks and containers utilize Micromatic RSV valves and couplings. These couplings are designed to prevent contamination of DEF. They have a dry-break mechanism that minimizes the exposure of DEF to the environment during connection and disconnection, maintaining the purity of the fluid

    DEF tank setup

     

    These couplings also help to eliminate drips or spills. Even a small amount of DEF fluid can corrode metals, so the dry-break feature is vital to protect any equipment around your DEF pump and tank.

    Valve for DEF RSV Series

    RSV Coupler

    Dispense Coupler

    RSV Drum/Tank Valve

     

    RSV couplings are the same type of couplings used on beer kegs and other chemical containers. There is a valve in the tank or drum, and there is the coupler on your pump or suction hose.

    There are two different types of Micromatic couplers: 3-key and 4-key. The reason for this difference is to prevent cross-contamination of equipment. For example, it prevents you from coupling a DEF pump to a tank containing some other chemical.

     

    How to Connect the Micro Matic RSV Dispense Coupler

     

    DEF Pump Options

    Due to the specific applications and the limited materials that are compatible with it, manufacturers have designed pumps and pump units specifically for DEF. There are 12-volt options available for mobile applications as well as stainless steel centrifugal pumps for bulk transfer.

     

    12-Volt DEF Pumps

     

    115-Volt DEF Pumps

     

    Air Operated DEF Pumps

     

    DEF Pump Kits

    Understanding that DEF is only compatible with certain materials, you must be careful when selecting a pump, but then you have to piece together a hose, nozzle, meter, and tank that is compatible. This is time-consuming and nerve-racking if you are not certain that an item will work with DEF.

    DEF pump manufacturers understand this and offer comprehensive solutions. There are several DEF pump kits that include a pump, hose, RSV coupler, and all the other appropriate fittings needed. These kits are often designed to hang off an IBC tote or 275-gallon shuttle. Some of these kits will even include a tank.

     

    DEF Pump Kits for Cage Tanks/IBC Totes

    12-Volt Kits:

     

    110-Volt Kits:

     

    DEF Pump Kits with Tank

    DEF Tank

    58 Gallon Tank Kit: PUPPT58

    116 Gallon Tank Kit: PUPPT116

    135 Gallon Tank Kit: DP2512-AE-135

     

    DEF Pumping Accessories

    Your pump's compatibility with DEF is vital, as are the accessories you use to handle it. Here are some essential accessories to consider and the types that work with DEF:

     

    DEF Tanks

    Polyethylene and stainless steel are the best materials for DEF storage. Poly is much more affordable. You can use just about any poly tank but you will want to ensure that the tank is properly sealed up and equipped with dry-break couplers to preserve the purity of your DEF.

    As mentioned earlier RSV couplers are the common method to ensure closed system transfer. These can be added to a tank if you do not have them. The RSV tank valves are made to fit into different thread types. If you use a 275-gallon IBC tote/Cage tank, you can replace the lid with one that will fit an RSV coupler.

     

    DEF Tank Options:

     

    DEF Hose

    EPDM rubber is the preferred hose to use for DEF. Hose fittings should be either polypropylene or stainless steel. There are also poly and stainless hose reels designed to handle DEF.

     

    Other DEF Accessories:

     

    Let Us Know if You Need Help

    DEF is a uniquid fluid with properties that dictate that you use the right type of pump and accessories to handle it safely. Fortunately, the pumps that work with DEF are clearly designed to do so. If you have questions about whether or not a specific product will work for DEF let us know.

     

    Shane Blomendahl, Author

    Tech Ag & Industrial Sales

    Shane Blomendahl is a tech sales veteran at Dultmeier Sales with over 10+ years of experience in liquid handling products covering several industries and applications.

    Learn More About Author

    Fertigation & Chemigation Injection Systems for Irrigation

    Injecting a liquid into a center pivot is an effective way to deliver nutrients to crops later in the growing season. Getting a fertigation or chemigation system setup is pretty straightforward, but there are some key aspects that you must get right to avoid any issues.

    So if you are not familiar with the type of pump you need, not to mention the other components that make it all work, this article will give you the information you need. Let's get to it.

     

    Components Needed for Injecting Fertilizer or Chemical into a Center Pivot Irrigation System

    The main components needed to inject fertilizer are the pump, check valves, hose, strainer, and tank. Several types will work as long as they meet the necessary size, flow, and compatibility requirements.

    • Positive Displacement Pump
    • Check Valve
    • Tank
    • Hose/Plumbing
    • Strainer

     

    It is important to note that in addition to the fertilizer components we discuss in this guide, you also need a chemigation backflow preventer or check valve on the well. The fertilizer is injected downstream from this valve. The specifics are dictated by local regulations. This chemigation check valve prevents chemicals or fertilizer from getting into the well and contaminating groundwater.

    Pivot Iinjection Diagram

    These chemigation check valves are not sold by Dultmeier sales. For more information, you can check out this article from North Dakota State University. You can also check with your pivot dealer.

     

    Injection Pump for Fertigation or Chemigation

    If you want to apply fertilizer or chemicals through a center pivot you need a pump. That may be obvious, but you cannot use just any type of pump. While centrifugal pumps are commonly used to transfer fertilizer they will not be effective when it comes to injecting fertilizer into a pivot or any other irrigation pipe.

    You need a positive displacement pump to inject liquids into the center pivot or irrigation pipe. This is a type of pump that uses mechanical means to physically move it fixed amount of fluid with each stroke or rotation. These pumps create higher pressure and central pumps and they can overcome the existing pressure in the irrigation line.

    There are different types of positive displacement pumps. Piston pumps are commonly used when injecting into an irrigation line but a diaphragm pump can also be used. These injection pumps are rated in gallons per hour. In addition to moving the liquid, the pump also serves as the metering device.

    These pumps can deliver a precise amount of liquid into the irrigation pipe, consistently with each stroke. The rate can be adjusted according to the amount of liquid you need to apply.

     

    Irrigation Injection Pump Options

    10620 Metering Pump

    EZ Meter Piston Pumps

    • Available in 5-30 GPH or 10-100 GPH
    • Up to 150 PSI
    • Wettable parts made of stainless steel and polypropylene, Teflon available
    • Motors available in 12-volt, single-phase 110-220 volt, and three-phase 220-440 volt
    • Easily repairable

    View all the options EZ Meter pump options here.

     

    Check Valve

    We already talked about the chemigation check valve in the irrigation line to prevent backflow into the well. There is another check valve that is needed for the fertigation system. This is installed in the injection port. They ensure fertilizer is released in the center of the pipe, providing even dispersion. 

    Pivot Injection Diagram Fig 2

    These ensure only fertilizer gets in and nothing leaks when the pump is not running. They also provide back pressure to ensure the pump meters are accurate.

     

    Storage Tank

    The tank is pretty straightforward whether you are using a stationary tank or you have a nurse trailer, you must have a vessel to hold your fertilizer. Flat-bottom vertical storage tanks are very common and they are rated to handle heavy fertilizers.

    Poly Vertical Tanks Tanks for Fertigation:

     

    Hose/Plumbing

    The hose that you use might seem like an afterthought, but the wrong hose could give you a lot of trouble. Just like with the pump, the hose needs to be constructed of material compatible with the fertilizer you are using. For nitrogen fertilizers, EPDM rubber hose works great. 

    You will need a reinforced suction hose on the inlet side of your pump. This means that from the supply tank to the pump. This hose should also have an inside diameter that is at least the size of the pump inlet. Using a smaller diameter hose can restrict the flow to the pump, damaging the pump and keeping you from hitting your application rate.

    The discharge hose does not need to be rated for suction. It should be rated to handle some pressure, the EZ Meter pumps from John Blue can produce 150 PSI. The nature of how these pumps operate does create pulsing. This means that your discharge hose will jump around a bit.  So be sure it won't rub on anything that could wear a hole in it during operation.

    Pivot Injection Diagram Fig 3

    This is a typical plumbing diagram for injecting metering pumps.

     

    Rinsing the pump is important. You can make it easier to do this by installing a 3-way valve somewhere in the suction line. This would allow you to switch from the fertilizer tank to a freshwater source. You can also use a three-way valve in the outlet of the tank so you can both withdraw and fill the tank without disconnecting the pump.

    Pivot Injection Diagram Fig 4

     

    Filters

    It is also vital to use a strainer in the suction line. This strainer should also be at least the size of the inlet port on the pump. A piston pump does not handle solid particles well, so the screen should have a fine mesh. The manufacturer of our piston pumps, John Blue, recommends an 80 mesh screen size to protect the pump.

    80 Mesh Line Strainer

     

    Final Thought

    With the right equipment and setup, you can deliver the nutrients your crops need through your irrigation system. Remember that the correct pump is vital to achieving the accurate results you want. Plumbing things correctly will help prolong the life of the pump and save you time.

     

    Shane Blomendahl, Author

    Tech Ag & Industrial Sales

    Shane Blomendahl is a tech sales veteran at Dultmeier Sales with over 10+ years of experience in liquid handling products covering several industries and applications.

    Learn More About Author

    (0) High-Flow Diesel Transfer: How Fast Can I Fill?

    Whether it's farming, construction, or mining, the seamless supply of fuel to your equipment is vital to maintaining productivity. Using the right diesel transfer pump can keep refueling from becoming a bottleneck in your operation.

    Several options are available for refilling equipment and bulk transfer of diesel fuel. I have been working with customers to identify efficient ways to refuel equipment for several years. Using that experience and customer feedback, I will break down the options and lay out the best diesel transfer units for several scenarios.

     

    Getting Started: Diesel Transfer Pump Options

    Diesel transfer pumps come in many forms to suit various needs. Two common types used for refueling and bulk transfer are rotary vane pumps and centrifugal Pumps. Because diesel is not as volatile as gasoline, there are typically different pumps or safety features required when pumping gasoline. In this article, we are solely talking about diesel fuel pumps and systems.

     

    Mobile Fueling Options

    When you are in the middle of a harvest or a construction project, you need to get fuel onsite. This calls for mobile fuel transfer options that run off the power available. Typically this means 12-volt batteries, hydraulic motors, or gas/diesel engines.

     

    12-Volt Rotary Vane Pump Units

    NX25 12 Volt Rotary Vane Fuel Pump

    You are probably familiar with the 12-volt rotary vane pumps used for mobile fueling. These are the 12-volt pumps that are installed right on top of a fuel tank. Often the pump manufacturer such as GPI or Fill-Rite, will package their pumps as kits. These kits generally include a suction pipe that fits into the pump inlet, a 3/4" or 1" discharge hose, a fuel nozzle, and an optional meter. These pumps feature a 2-inch male NPT inlet that easily attaches to standard 2" tank bung threads.

     

    12-Volt Fuel Pump Specs:

    • Flow rate: Up to 25 gallons per minute (GPM)
    • Manufacturers: GPI, Fill-rite, Piusi
    • Inlet: 2-inch male NPT
    • Discharge Hose: 3/4" or 1"
    • Features: Fuel nozzle, optional meter, suction pipe

     

    High-Flow 12-Volt Fuel Pump Options:

    GPI Model: GIV25-012AD

    Filrite Model: FRNX25-12V

    Piusi Model: PUEX100-PO

     

    RELATED: Mechanical Vs Digital Meter: Which One is Best for My Application (not yet written)

    These 12-volt pump units are relied on a lot for mobile refueling applications. These pumps are reliable and can last for years. One downside to this type of pump is the flow rate. The highest flow 12-volt fuel pumps are rated to about 25 gallons per minute.

    That is pretty good for most scenarios but it does not take into account the loss of flow from the hose, nozzle, fuel filters, and any elevation you are trying to overcome. (Think pumping fuel up into a combine or a large excavator.) When all of this is taken into account, your flow may be greatly reduced.

    Pressure loss is a tricky thing to determine, but you can see charts on this page that will help know the pressure loss in your plumbing setup. We will get to ways to get the most flow out of your pump in a moment, but first, let's look at some other high-flow pump options.

     

    Engine Driven Diesel Pump Units

    So what if these 12-volt pumps won't cut it? I mean, If you are filling a 300-gallon fuel tank at 15 gallons per minute, it is going to take some time. That is where engine-driven centrifugal pump units come into play. These units offer more flow potential than the smaller 12-volt pumps. That is why we have built diesel fuel pump units to offer a more efficient refueling option for large equipment.

     

    High Volume Diesel Fuel Transfer Systems

     

    Dultmeier High-Flow Diesel Unit Specs:

    • Flow rate: Up to 60 GPM
    • Pump Type: Centrifugal pump units
    • Inlet Hose: 1-inch or 1-1/2 inch
    • Flow Rate (Assembled):
    • 1-inch version: 30 GPM
    • 1-1/2 inch version: 60 GPM
    • Additional Features: Shut-off nozzle, filter, hose, reel, meter (optional)

     

    On its own, a two-inch diesel pump driven by a gas engine is capable of moving over 150 gallons per minute. The cost of these pump and engine units is often comparable to the 12-volt pumps that can move 25 gallons per minute. Now, that may sound too good to be true, so let me explain.

    When you are filling equipment you will likely need all of these things in addition to your pump: a shut-off nozzle, a filter, plenty of hose, a reel, and possibly even a meter. The 150 gallons per minute flow from a gas-engine driven centrifugal pump is only achievable with the right size hose. For a flow rate of 150 gallons, you would not want to use anything less than a 2-inch hose (inside diameter). Smaller hoses will restrict flow and so will a fuel filter, auto nozzle, meter, and hose reel.

    Even though these items reduce the overall flow rate you are still getting a lot more flow from one of these units compared to the 12-volt rotary vane pumps. Especially when pumping vertically into a combine or other large piece of equipment.

    We build a 1-inch version and a 1-1/2-inch version. Assembled with filters, nozzles, hose reels, etc., they will still deliver a flow rate of 30 and 60 gallons per minute respectively. This flow rate is at the nozzle and after pushing through 35 ft of hose. The primary limiting factor is the fuel filters used on each unit.

    DUFPU1P 30 GPM Fuel Transfer Pump

    30 Gpm Unit: DUFPU1P

    DUFPU1.5P 60 GPM Fuel Transfer Pump

    60 Gpm Unit: DUFPU1.5P

    These units are available in various configurations. Base units have recoil start engines and no meters, but you can upgrade to an electric start gas engine and add a meter. Contact one of our team members to learn more.

     

    Stationary/Bulk Storage Tank Pumps

    If you have a tanker truck to unload or want to fill your fuel trailers from bulk storage tanks, then you probably need more than a 30 or even 60-gallon flow rate. Well, as we discussed earlier, centrifugal diesel transfer pumps can achieve much higher flow rates than this, you just need the right plumbing. Let's examine the bulk diesel transfer pump options.

     

    Electric Motor Driven Centrifugal Pump Units for Diesel

    As referenced above, a two-inch centrifugal pump is capable of well over 150 gallons per minute. But you don't have to limit yourself, for bulk transfer you can use larger pumps. Three-inch pumps can potentially move 300-500 gallons per minute or more. There are also plenty of larger diesel transfer options if your scenario requires it.

    Options:

    • Flow rate: 50 gallons per minute and up
    • Explosion-proof motors available
    • Common 2-3 inch port sizes

     

    Popular Electric Motor Diesel Pump Units:

    DUMP3030C Diesel Pump Unit

    Diesel Unit: DUMP3030C

    GR81-1/2-3P Centrifugal Pump with Explosion Proof Motor

    Explosion Proof Motors GR81-1/2-3P

     

    How to Choose a Diesel Transfer Pump for Bulk/Storage Tank

    When you are looking for a high-flow transfer pump to handle bulk diesel transfer or truck unloading, here are the main things to consider:

    • Flow Rate: Decide how quickly you need to move your fuel. For example, if you want to fill a 1000-gallon fuel trailer in 10 minutes, you'll need a pump with a flow rate of at least 100 gallons per minute (GPM).
    • Power Source: Determine what pump drive type will work best for you depending on available power sources and site conditions.
    • Self-priming vs Straight: Choose self-priming If the pump needs to lift fuel from a lower level, such as from an underground tank. Use a straight centrifugal pump when the pump inlet is permanently lower than the liquid level of the tank.
    • Material Compatibility: Select materials that are compatible with diesel to prevent corrosion and ensure longevity. Metals: stainless, cast iron, aluminum, ductile iron, Rubbers: nitrile, buna, Viton®.

     

    You might be asking, "But what about filters or fuel nozzles, won't those limit the flow rate?". They certainly can if they are not rated to accommodate higher flow rates. Fortunately, there are high-volume filters and nozzles available for these applications.

    Viking series filters are designed for high-volume fuel transfer. There are different models and they will handle 120-300 gallons per minute.

     

    Viking Filters:

    40188 Viking Filter Housing

    Viking 2

    Viking 3F

    There are also high-flow fuel nozzles for flow of 100 gpm or more. Of course, you can always use a brass or stainless steel ball valve as well.

    2-inch Fuel Nozzles: Morrison 2-Inch 75 Degree Nozzle

     

    How to Maximize Your Diesel Pump Flow Rate

    To maximize the flow rate from a diesel pump, it's essential to consider several factors that can influence performance, including hose size, fitting size, filters, nozzle, and vents. Let's break down each component and how they contribute to optimizing flow rate.

     

    Hose Size

    The flow rate of fuel through a hose depends on the size of the hose's inside diameter. If you double the diameter of the hose, the flow rate can increase significantly. Bigger hoses reduce friction inside the hose. Smaller hoses create more resistance, which slows down the flow of fuel. A larger hose allows the fuel to flow more freely and quickly.

    Tips to Maximize Flow:

    • For discharge hose, use the largest hose diameter possible to minimize friction loss. Example: for a 2-inch pump, use a 2-inch or larger inside diameter hose.
    • Ensure the hose length is only as long as necessary; longer hoses can reduce the flow rate.
    • Ensure the suction hose or pipe (this is any pipe or hose prior to the pump inlet) is large enough for the pump. Again, for a 2-inch pump, you need at least a 2-inch (inside diameter) suction hose or pipe. Same for 3-inch, 4-inch, etc.

     

    Fitting Size

    Similar to hose size, the diameter of the fittings used in the diesel pump system must be adequate to handle the desired flow rate without creating bottlenecks. You might have a 2-inch discharge hose, but if you use a 1-1/2 inch elbow or swivel, that will result in a flow reduction. If you have multiple points where there is a smaller fluid path, this really adds up.

    Tips to Maximize Flow:

    • Select fittings that match or exceed the inner diameter of your hoses.
    • Avoid unnecessary bends, elbows, and reducers that can increase friction and reduce flow.

     

    Filters

    Filters are crucial for maintaining fuel quality but can introduce resistance and reduce flow rate if not appropriately sized or maintained. There are two size dimensions to consider with a fuel filter: port size and filter size.

    Filter port size refers to the inlet and outlet on the filter. As a rule of thumb use a filter head with ports that match your hose size and pump outlet. Not all filters flow the same even if they have the same port size. One filter may allow a max flow of 18 GPM while another may be designed for 25 GPM. We can provide the flow rate of various filter types to find the best fit for your operation.

    The reason for the different flow capabilities is due to the type of filter element inside the filter housing. These are available in various levels of filtration. Often this is measured in micron size. The smaller the number, the smaller the particles it will filter. 2, 10, and 30 microns are common filter sizes for fuel. While finer filtration is good, it can significantly affect your flow rate.

     

    Tips to Maximize Flow:

    • Choose filters with a flow rating that matches or exceeds your pump's flow rate.
    • Regularly maintain and clean filters to prevent clogging and flow restriction.
    • Use 10 microns for most applications, and 30 microns for heavier fuels like diesel fuel.


    Shop Fuel Filters

     

    Nozzle

    Discharge nozzles are necessary to stop flow when filing is complete, but these nozzles, especially automatic nozzles, can restrict flow. It is important to know that not all nozzles will flow the same even if they appear the same size.

    You can see high-flow fuel nozzles here. There are typical nozzles that will handle 15-20 GPM, but also larger auto nozzles that can handle flows of 75 and even 100 GPM.

    Tips to Maximize Flow:

    Only use automatic or "service station" style nozzles when needed. For bulk transfer use ball valves instead as your shut-off. These have higher flow rates.

     

    Vents

    Proper tank venting is essential to maximize your flow. You must be able to remove air from your tank to add fuel, and you must allow air into your tank to withdraw fuel.

    Venting is not just about flow rates, it is also a safety issue (see what can happen here). Diesel fumes can be flammable. Ventilation allows these fumes to escape safely, reducing the flammable vapors inside the tank. This minimizes the risk of fire or explosion.

    • Tips to Maximize Flow: Ask tank manufacturers/retailers to help size vents
    • Check the vent regularly for clogs or damage

     

    Time & Money Saving Diesel Pump Accessories

    0087 Hose Swivel

    Hose swivels are a great tool that makes handling your fuel nozzle easier, but they also keep your hose from wearing out at the ends from the natural twisting and bending that occurs over time when the hose is handled.

    View fuel swivel options and other petroleum accessories here.

     

    1931-2 Malleable Union

    Similar to a swivel, but these fittings are not "live" swivels. Pipe unions allow for the quick disconnection of pipes without the need to rotate them. This is particularly useful in tight spaces where turning a long pipe might be impractical. You can see the different size unions for fuel here.

     

    Hose Reels

    How a hose is handled and stored has a profound effect on its lifespan. For example, a hose rolled up and hung on a hook can wear at the pressure point over time. A hose drug on gravel or rough concrete will suffer from abrasion and be prone to potential leaks.

    A hose reel helps to avoid these issues. It also removes the hard labor of rolling up and unraveling a hose. You will also avoid the potential safety hazards from a hose lying on the ground.

    Electronic rewind and spring rewind hose reels are available to work with fuel and they come in sizes that can handle up to three-inch hoses:

     

    1 Inch Spring Rewind Fuel Hose Reels:

     

    1-1/2 Inch Spring Rewind Fuel Hose Reel:

     

    Conclusion

    In the world of demanding industries like farming and construction, the efficiency of refueling operations is crucial. The right diesel transfer pump can transform refueling from a logistical headache into a smooth, efficient process that keeps your equipment running without delays.

    There are many options, understanding the specific needs of your operation and the technical aspects of these pumps will help you make an informed choice. Always consider flow rates, power sources, and additional features like filters and nozzles to optimize your setup for maximum productivity.

    You can reach out to one of our sales team directly via email or phone if you have any more questions!

     

    Shane Blomendahl, Author

    Tech Ag & Industrial Sales

    Shane Blomendahl is a tech sales veteran at Dultmeier Sales with over 10+ years of experience in liquid handling products covering several industries and applications.

    Learn More About Author

    Understanding the Numbers on a Sprayer Nozzle: A Comprehensive Guide

    It is no secret that there are quite a few options when it comes to sprayer tips. In fact, our Liquid Handling Catalog has over 30 pages dedicated to different spray nozzles! Fortunately, there is an international standard in place to ensure the consistency and performance of sprayer nozzles used in agriculture. This is crucial because nozzles need to perform reliably to apply pesticides, herbicides, and fertilizers effectively.

    This standard, specifically known as ISO 10625, defines these specific nozzle characteristics: spray pattern, flow rate, and droplet size. The standard achieves this by implementing a numbering system that helps identify and categorize nozzles based on their performance characteristics and specifications.

     

    Numbering System for Spray Nozzles

    Now that we have the reasoning behind the numbers out of the way, we can examine what these numbers tell us.

    Each spray nozzle is assigned an identification code. This code may consist of letters and numbers. It provides the nozzle type, orifice size, spray pattern/spray angle, and material of construction.

    • Nozzle Type: Manufacturer nozzle type/name. Denotes specific designs or features specific to this nozzle series such as extended range (psi), twin fans, droplet size, etc.
    • Spray Angle: The numbering system specifies the angle of the fan produced by the nozzle. Nozzle spray patterns have a vital role in effective coverage. For more details, take a look at this chart that shows the theoretical coverage of nozzles at different angles and spray heights.
    • Nozzle Size: The numbering system classifies nozzles based on their flow rate at a standard pressure (40 psi). This helps in selecting nozzles that deliver the correct amount of chemical per unit area.
    • Material/Features: The final part of the code will include information about the nozzle material (e.g., brass, stainless steel, plastic). It can also note other nozzle features such as a specific shape or characteristic of the spray pattern.

     

    Let's look at an example of nozzle numbering using an "XR 110-04 VK" spray tip:

    Spray Nozzle Numbers

     

    Here is the breakdown of what each section of this sprayer nozzle number/code means for this specific nozzle:

    • XR: This indicates the type or series of nozzle, in this case, the XR TeeJet, which stands for "extended range". Extended range refers to the wide range of PSI the nozzle will operate at.
    • 110: Represents the spray angle in degrees. This particular spray tip, therefore, will spray at a 110-degree angle.
    • 04: Indicates the flow rate. In this case, it signifies a flow rate of 0.4 GPM at 40 PSI.
    • VK: Describes the material of the nozzle. "VK" stands for VisiFlo ceramic. This indicates that the nozzle tip is made of ceramic and follows the VisiFlo* color code.

    *Just a quick note, VisiFlo was the color coding system started by Teejet to categorize different-size nozzles. This system was adopted by the ISO standard that is used today. The code assigns a color to each nozzle side:

    ISO Nozzle Color Code

    Not all spray tips make it this easy. In some cases, spray tip numbers are not displayed as clearly on the nozzle face but instead may be labeled on the side or base of the nozzle. This variance in numbering location is because manufacturers often offer numerous nozzle types that vary in design, which of course further differs for each manufacturer.

    Further complicating matters, some spray nozzle brands do not adhere to the ISO color coding system. To illustrate these differences, let's take a look at a few examples.

     

    Example Sprayer Nozzle Numbers & Comparisons

    First, lets look at two nozzles from the same manufacturer and family/type. The only difference between the two is the sizes or flow rate:

     

    Spray Nozzle Numbers Fig 1The red nozzle is an 04 size and the yellow nozzle is an 02 nozzle.

     

    Now, sometimes the numbers are not this clearly displayed. Both of these are Teejet nozzles, but they are different types. You can clearly see the numbers on the XR spray tip but this other nozzle does not have the numbers listed in this form.

    Spray Nozzle Numbers: Red vs Red

    You can see that the nozzle does have an 04 on the tip, this along with the color indicates the size, as all red nozzles are going to be an 04 size. It does say Turbo and Teejet on the side but it is hard to see.

    You will notice that there is no indication of the spray angle or the material. But, if we look up a TT nozzle in our catalog you can see that a Turbo TeeJet is going to have a 110-degree tapered flat fan and is made of polymer. This is an example where the manufacturer, because of the unique design of their spray tip, has only labeled the nozzle with the nozzle series (Turbo Teejet/TT) and the size (04).

    Since all sizes within this family of nozzles share the same spray angle and material, the nozzle type is understood to stand in for this information without it having to be shown directly on the tip as with the XR nozzle. If you are uncertain or have a nozzle that lacks numbers clearly displayed on it, call us, we can help you!

     

    In our next photo, we have two nearly identical nozzles. Same brand, same type, same size, and color; however, there is a significant difference in the spray pattern produced by each one. Once more, the numbers tell the story.

    Spray Nozzle Numbers Fig 2

     

    First Number: We know the first set of numbers is the spray angle. So here, the nozzle on the left produces an 80-degree fan, while the nozzle on the right will produce a 110-degree fan.

    Second Number: We know this portion of the number signifies the size of the nozzle, which in this instance is 04 for both. We know this from the number as well as the color.

    Letters: This is where things start to get interesting. The nozzle on the left does not have any prefix numbers (More on this in a bit). Conversely, the nozzle on the right is an XR tip. As we explained earlier, this means it is an extended-range flat fan tip. The final set of letters indicates the material of the tip, which for the nozzle on the left is VS (stainless) and on the right is VK (ceramic).

     

    But what about that "E" before the VS on our first nozzle? This notes that the nozzle has a special spray fan. It is not the standard tapered flat fan found on most ag sprayer nozzles. Instead the "E" tells us that the nozzle produces an even spray pattern.

    This one little letter makes these two nozzles very different. The XR nozzle will give you a tapered flan fan pattern. It applies the most spray in the center of the pattern, with less towards the edges. This is designed to overlap with other nozzles on a boom. An even fan spray nozzle, on the other hand, produces a uniform spray pattern across its entire width. This type is ideal for band spraying, where a consistent amount of spray is needed over a specific strip or band. Unlike the tapered flat fan nozzle, it does not taper off at the edges.

    Spray Patterns

    Image from Teejet.com

     

    For our last comparison, let's look at Greenleaf TurboDrop nozzles. These nozzles all consist of two pieces that each have different numbers on them. This can lead to some confusion. The reason for the two sets of numbers is that they are made up of two sections: a venturi pre-orifice and a tip/cap.

    Greenleaf Nozzle Numbers

     

    Below we have a TDXL11004 TurboDrop series nozzle. The venturi, which is the red portion, has a size number on the side. For the TDXL11004, that number is TD 04. This follows the same color code and size code as other flat fan nozzles.

    Greenleaf Nozzle Numbers Fig 1

     

    The tip/cap, which is white for this particular nozzle, will also have a number. You will notice that our number is 110-08 and the color is white. If you remember, a nozzle with 04 in the number will have a flow of 0.4 GPM. So what is this 08 tip doing on a nozzle that says it is rated for 0.4 GPM?

    Greenleaf Nozzle Numbers Fig 2

     

    Greenleaf TurboDrop nozzles are designed to reduce drift and still offer excellent coverage. Their two-piece design pulls air into the droplets to create a consistent droplet size. The venturi or pre-orifice controls the rate while the tip/cap produces the fan. Consider the TDXL11004, On its own the white 08 tip/cap could be used as a standard 11008 spray tip that will produce finer droplets.

    When combined with the venturi, though, it becomes an effective air-induction nozzle. The tip is double the size of the pre-orifice and this difference is what helps pull air into the nozzle resulting in larger air-filled droplets.

     

    Using These Numbers: Spray Nozzle Charts

    Once you understand spray nozzle numbering, you'll be able to better choose the right nozzle for your specific application. Identifying the number on the nozzle is just half the battle. You will also need to know how to read a spray nozzle chart to compare nozzles and examine the different characteristics of each type.

    A spray nozzle chart provides all the necessary information you need to determine how a nozzle will perform under various operating pressures. These charts are provided by the nozzle manufacturers, TeeJet, Wilger, Hypro, Greenleaf, etc. Nearly all spray charts will display the following information:

    1. Flow Rate: The amount of liquid delivered per minute at a specified pressure, usually measured in gallons per minute (GPM) at 40 psi.
    2. Spray Angle: The width of the spray pattern produced by the nozzle, measured in degrees.
    3. Droplet Size: Classification of the droplet size produced, which can range from very fine to extremely coarse.
    4. Operating Pressure: The range of pressure that the nozzle will perform as intended, usually measured in pounds per square inch (PSI).
    5. Application Rate: The amount of liquid applied per unit area, expressed in gallons per acre (GPA).

    Spray nozzle charts warrant a more detailed discussion to thoroughly understand them. While we won't get into those details in this guide, for more information check out this article on how to use sprayer nozzle charts.

     

    Spray Nozzle Selection Tools

    Many spray nozzle manufacturers now also offer electronic spray tip selection tools that offer nozzle recommendations based on your specific application inputs. These tools make nozzle selection easy, but a basic understanding of the numbers behind the nozzle is still important when using these tools:

     

    Conclusion

    Understanding the numbering system for spray nozzles is crucial for selecting the right one for your application. The ISO 10625 standard provides a clear and consistent method to identify and categorize nozzles based on their performance characteristics.

    Dultmeier handles a large quantity of TeeJet, Wilger, Greenleaf, and Hypro sprayer nozzles in stock and ready to ship. If you need assistance sizing and selecting a nozzle, don't hesitate to reach out for expert help.

     

    Shane Blomendahl, Author

    Tech Ag & Industrial Sales

    Shane Blomendahl is a tech sales veteran at Dultmeier Sales with over 10+ years of experience in liquid handling products covering several industries and applications.

    Learn More About Author

    Gallons Per Minute (GPM) Calculator: Determine Spray Nozzle and Orifice Size

    Sprayer nozzle or fertilizer orifice selection requires that you know the flow rate or size of tip that you need. This tool will help you quickly and accurately calculate the flow rate required per sprayer nozzle to apply your desired application rate.

     

    GPM Calculator



     

    Using This Information

    With this information, you can use a sprayer nozzle chart to find a nozzle that will apply this flow rate. For more information, refer to this complete guide to finding a nozzle size, that breaks down using a spray nozzle nozzle chart. If you need help sizing nozzles for a PWM system then refer to this guide.

     

    Understanding The Formula In This Calculator

    We use the GPM formula to determine the spray nozzle or orifice size needed for your specific sprayer and application requirements. The formula looks like this:

    Formula for GPM

    And here is what each value in the equation represents:

    • GPM (Gallons Per Minute): This is the flow rate of each nozzle on the sprayer. It tells you how many gallons of liquid are being sprayed out of each nozzle every minute.
    • GPA (Gallons Per Acre): This is the amount of liquid you want to apply per acre. Your target application rate.
    • mph (Miles Per Hour): This is the speed at which you're driving the sprayer, tractor, UTV, etc.
    • W (Width in Inches): This is the nozzle spacing from center to center of each nozzle.
    • 5,940: This is a constant number used to convert the units back into a number that is easy to work with. It is a derivative of the different units involved in this formula. The important part is that you know you need to use 5940 in this formula.

     

    Example Calculation:

    You want to apply a rate of 20 gallons per acre. The average speed you will spray at is 5 mph. The distance between each spray nozzle is 20 inches (center to center).

    In this case, you would Input these values into the calculator:

    1. GPA: 20
    2. Speed: 5
    3. Nozzle Spacing: 20

    Click "Calculate GPM" and you get:

    GPM: Approximately 0.34

    This means each nozzle should deliver 0.34 gallons per minute to apply 20 gallons per acre at a speed of 5 mph with nozzles spaced 20 inches apart.

    This formula works for broadband spraying applications with overlapping flat fan nozzles as well as solid stream nozzles used on fertilizer bars and applicators.

     

    Finding a Spray Nozzle

    Nozzle size is a major factor when selecting a spray nozzle but it is not the only thing to consider. You also should consult the label on the product you apply for guidance on the specific spray nozzle requirements for your application.

    Dultmeier Sales carries a wide range of sprayer nozzles for nearly any application:

    • Broadcast
    • PWM
    • Drift-control
    • Pre or Post-emergent
    • Contact or systemic
    • Soil applied
    • Insecticides
    • Fungicides
    • Herbicides
    • Fertilizer

    If you are looking for guidance, get in touch with us and we can help you with sizing and finding a sprayer nozzle.

     

    Shane Blomendahl, Author

    Tech Ag & Industrial Sales

    Shane Blomendahl is a tech sales veteran at Dultmeier Sales with over 10+ years of experience in liquid handling products covering several industries and applications.

    Learn More About Author

     

    Blog Headimg

    A Comprehensive Guide to Pre-Season Preparation for Farmers: Maximizing Yield and Efficiency

     

    This guide focuses on the unique needs and challenges of row crop farming, emphasizing efficient use of resources, technology integration, and sustainable practices to enhance productivity and profitability.

     

    1. Soil Testing and Field Preparation

    Conduct Detailed Soil Tests: Test each field for pH, nutrient levels, and soil composition to guide precise fertilizer and lime applications. Soil sample analysis can be done by your local soil laboratory or extension service.

    Field Preparation: Implement tillage practices suited to your soil type and crop needs. Minimum tillage can preserve soil structure and moisture, while conventional tillage may be necessary in certain conditions to prepare a seedbed, control weeds, or incorporate amendments.

     

    2. Crop Selection and Rotation

    Select Adapted Varieties: Choose crop varieties with high yield potential, disease resistance, and adaptability to your climate. Consider traits such as drought tolerance or herbicide resistance as applicable.

    Implement Crop Rotation: Rotate crops to break pest and disease cycles, improve soil health, and optimize nutrient use. Plan rotations to include legumes to fix nitrogen, reducing the need for synthetic fertilizers.

     

    3. Seed Treatment and Planting

    Use Treated Seeds: Opt for seeds treated with fungicides and insecticides to protect against early-season pests and diseases. Consider seed treatments that enhance germination under cold or wet periods or seed varieties which tolerate drought or high-wind conditions.

    Precision Planting: Use precision planting equipment to ensure uniform seed depth and spacing. Calibrate planters for specific seed sizes and adjust planting rates based on germination tests and field conditions.

     

    4. Water Management

    Irrigation Efficiency: For irrigated fields, optimize irrigation schedules and methods (pivot, drip, or furrow) based on soil moisture monitoring and crop water needs. Consider technology like soil moisture sensors and weather-based irrigation scheduling.

    Drainage: Ensure proper field drainage to prevent waterlogging and enhance root development. Install or maintain drainage systems where necessary.

     

    5. Integrated Pest Management (IPM)

    Scouting and Monitoring: Regularly scout fields for pest and weed pressure. Use thresholds to make informed decisions about the need for interventions.

    Chemical and Biological Controls: Use targeted chemical controls when necessary and consider biological controls like beneficial insects for sustainable pest management.

     

    6. Machinery Maintenance and Calibration

    Equipment Readiness: Ensure all planting, tillage, and spraying equipment is in good working order before the season starts. Perform necessary maintenance and repairs during the off-season.

    Planter Calibration: Precisely calibrate planting equipment to match seed size, type, and desired planting rate. Check and adjust downforce, seed tubes, and closing wheels to ensure optimal seed placement. Perform a short test swath of planted seeds to ensure all settings are correct before planting entire fields.

     

    7. Technology in Farming

    Adopt Precision Agriculture: Utilize GPS-guided equipment for precise planting, fertilizing, and spraying. Consider variable rate technology (VRT) for applying inputs based on soil and yield data.

    Data Management: Use farm management software to track field operations, input applications, and crop performance. Analyze data to make informed decisions for future seasons.

     

    8. Weather and Climate Adaptation

    Weather Tracking: Use weather forecasts and climate data to plan field operations and mitigate risks from extreme weather events.

    Resilience Practices: Implement practices to increase crop resilience against climate variability, such as cover cropping, diversified cropping systems, and conservation tillage.

     

    9. Economic Planning and Risk Management

    Cost Analysis: Conduct detailed cost analyses for each crop, considering input costs, projected yields, and market trends.

    Risk Management: Utilize crop insurance and marketing strategies (futures, options, contracts) to manage price and yield risks.

     

    10. Professional Development and Networking

    Continuous Learning: Stay updated on agronomic research, crop protection products, and new technologies through extension services, agricultural publications, and professional associations.

    Collaboration: Engage with local farming groups, cooperatives, and research institutions for shared learning, market opportunities, and collaborative projects. 

    (0) Choosing the Best Type of Flow Meter for Your Application

    Fillrite 807C Fuel Meter

     

    Flow meters are some of the most versatile and integral components in any fluid handling system. From agriculture chemical production to water treatment facilities, meters offer a reliable means to monitor how efficient your operation is and provide a tangible reading to identify potential issues within the plumbing system. This makes choosing the right flow meter for your application even more important. Selecting the wrong meter causes inaccuracies within your flow monitoring processes and creates inefficiencies throughout the rest of the system, not to mention significant unintended costs.

    Dultmeier Sales is here to ensure that doesn't happen.

    In this guide to flow meter selection, we'll take a look at several common meter types and the various applications in which they are used. We will also highlight some key considerations to keep in mind so that you always choose the best flow meter for your application needs. So, without further ado, let's get started.

     

    Understanding What a Flow Meter Does

    Simply put, a flow meter is a device that measures the flow of material-typically either liquids or gases-through a pipe. It determines how much material passes through the pipe (or hose) in a given period. It typically provides this measurement in units like gallons per minute (GPM), liters per second (L/s), or cubic feet per minute (CFM).

    While this concept is straightforward, selecting the right flow meter for your specific task, however, can be more complicated.

     

    Fill-Rite Mechanical and Digital Flow Meters

    Fill-Rite mechanical flow meters & digital flow meters

     

    How to Choose the Right Flow Meter

    First off, It is important to note that no two meters are exactly alike. Depending on application and metering needs, you may have several meter options or a single very specific one from which to choose. Complicating things further are the many external considerations your meter must satisfy in order to accomplish its intended purpose. As they say, the "devil is in the details," and the same goes for choosing the best flow meter for your application.

    Below are some key characteristics to keep in mind when selecting the proper flow meter:

    • Accuracy & Repeatability
    • Type of Fluid (liquid, gas, slurry, steam)
    • Density
    • Viscosity
    • Conductivity
    • Temperature
    • Pressure
    • Flammable/Oxidizer
    • Corrosiveness/Toxicity
    • Flow Range/Turndown
    • Materials of Construction
    • Environment/Location & System Configuration
    • Hygiene Requirements (pharmaceutical, food processing, etc.)
    • Costs
      • Initial Investment
      • Installation
      • Long-term Maintenance

    While the meter you ultimately select should ideally meet every factor above, ensuring it meets the most important ones for your operation will help guarantee you receive the best results. Let's dive into a few of the main ones on which you should focus.

    Accuracy & Repeatability

    Near the top of the list when evaluating flow meter specs is flow meter accuracy. Accuracy is how close a measurement is to the actual true value passing through a system. Expressed as a percentage (i.e. +/- 1%) accuracy represents how close the meter's output is to its calibrated parameters. Generally, the lower the percentage, the more accurate a meter is.

    However, accuracy is not the only side of the coin. Repeatability, or the production of like outcomes under the same conditions, is perhaps even more important when evaluating which flow meter to choose. This is because accuracy is only reliable so far as its consistency. As you can see below, repeatability is possible without high accuracy, but high accuracy is not achievable without repeatability.

    Flow Meter Accuracy and Repeatability

    Flow meter accuracy & repeatability



    If your flow readouts are unreliable-meaning you receive inconsistent results despite the same conditions-then you aren't gaining any value. Likewise, if your flow volume falls short of or exceeds your meter's rated flow range (also known as turndown), you won't receive accurate readings either.

    Precision readings go hand in hand with any well-tuned operation. Choosing the best flow meter accuracy and repeatability percentages that meet your application requirements ensures your system maintains the precision readings you desire.

    Liquid, Gas, or Semi-Liquid?

    The type of fluid you work with is another big factor when choosing which flow meter best fits your application. Fluid type breaks into four categories: gas, liquid, slurry, and vapor-each with its own unique characteristics.

    Properties such as fluid density, temperature, viscosity, and corrosiveness/acidity all must be determined before a final selection. This ensures you avoid choosing a flow meter incompatible with the fluid type you are attempting to measure. Electromagnetic flow meters, for example, won't work with non-conductive fluids like hydrocarbons. Likewise, few meter types are capable of measuring slurries because of their unique semi-liquid characteristics.

    How slurry particles behave between homogenous and heterogeneous mixtures.

    Illustration of how slurry particles behave between homogenous & heterogeneous mixtures



    Here is a short list of flow meter types commonly used for the four fluid categories:

    • Gas: Coriolis, Thermal Mass, Positive Displacement, Turbine, Variable Differential Pressure, Ultrasonic
    • Liquid: Coriolis. Thermal Mass, Positive Displacement, Variable Flow, Paddlewheel, Turbine, Variable Differential Pressure, Ultrasonic, Electromagnetic
    • Slurry: Coriolis, Electromagnetic, some subsets of Differential Pressure
    • Vapor: Vortex, Ultrasonic, Floating Element

    While not comprehensive, this list should offer a good starting point. That said, not every meter listed may work for your specific setup or needs. For instance, if your operation handles multiple fluids, you'll want to ensure that the meter you go with is compatible with all fluids-not just one. Otherwise, you likely spend valuable time calibrating your flow meter each time you handle a different product or troubleshooting why your inventories are off from your readouts.

    Location & System Configuration

    Meter location, as in real estate, is another major consideration. Will the flow meter be installed inside a controlled environment or outdoors in the elements? Is space a non-factor, or must size be considered? Certain flow meters even require stretches of straight pipe before and after the meter to generate accurate flow readings.

    As a rule of thumb, pipe lengths of 10X (where X = pipe diameter) are needed before and after a meter for straight runs of pipe. So, if your plumbing's diameter is 2" you would need 20" or approximately 2 feet of pipe before and after the flow meter. This goes for just about any meter type, but it is always best to check the manufacturer's specs.

    Also, keep in mind horizontal or vertical mounting. Some meters can be mounted in either orientation while others must be in one orientation or the other. Variable flow meters, for example, rely primarily on gravity in order to measure flow rate. Thus, they must be installed vertically to work. Determining how and where a meter will be installed while choosing a meter saves installation time and avoids costs related to unintended system reconfiguring.

    Differentiating Between Volumetric vs. Mass Flow

    Before we break down various flow meters, it is important to say a word on flow measurement. While there are many types of flow meters, most used today fall under two primary categories according to how they calculate flow: volumetric and mass.

    As their name suggests, volumetric flow meters measure flow by calculating the volume of a fluid. Flow is often directed through an intrusion metering device such as a turbine or orifice plate, which then measures fluid velocity proportionally to the volume of matter passing by. Volumetric flowmeters make up the majority of meter types today and include turbine, magnetic, positive displacement, ultrasonic, and vortex meters to name a few.

    Volume flow vs. mass flow within a cylinder

    Volume flow vs. mass flow within a cylinder



    Mass flow meters, meanwhile, calculate flow rate by measuring the mass of a fluid. Mass meters have become increasingly popular due to their precision performance and truer reading of product flow compared to older metering technologies. In the diagram above, for instance, the product volume significantly changes depending on the position of the piston-even as mass remains the same. Today, mass meters have more or less become synonymous with Coriolis mass meters, but other types do exist. We'll discuss how mass meters work later in the article.

    Whether you choose volumetric meters and mass meters depends on your application and metering needs, as well as your operational preferences and cost differences. In the end, you can still calculate volume to mass or mass to volume so long as the fluid density, surrounding temperature effects, and other conversion factors are all understood.

    Comparing Flow Meter Types

    There is, unfortunately, no such thing as a universal flow meter. Each flow meter type has fluids and applications for which it is well suited, and similarly, ones for which they are not. The following is a breakdown of some of the most common types of flow meters and the pros and cons of using each one.

    Positive Displacement Flow Meters

    Pros

    • Accurate across wide flow ranges
    • *Can handle very viscous fluids
    • Versatile applications-simple, reliable design
    • Require no power supply
    • Cost-effective

    *Thicker viscosity fluids create larger pressure losses & reductions in flow rates

    Cons

    • Requires medium to high-flow applications
    • Experience greater pressure drops
    • Larger/heavier than other meters
    • Not recommended for dirty fluids or gases
    • Some subsets require constant lubrication
    • Many moving components need regular maintenance and replacement

    Positive displacement (PD) meters consist of chambers featuring mechanical components that rotate in relation to volume flow. As fluid passes through, the reciprocating components-generally a type of gear, vane, or diaphragm-divides the fluid into fixed, metered volumetric units. The number of units rotated through within a specified time frame directly correlates to flow rate. Subtypes include screw meters, rotary vane meters, diaphragm meters, reciprocating or oscillating piston meters, and helical or oval gear meters.

     

    TCS 700 Series Rotary Fuel Meter with Register

    TCS 700 Series Rotary Fuel Meter with Register



    Since PD meters only measure flow while fluid passes through, they're ideal for applications where metering is crucial to calculate fluid usage. The TCS 700 series rotary vane meters, for example, are widely used in oil and gas custody transfer industries, while diaphragm meters are commonly installed on residential or municipal water and gas lines. Their fluid-driven design additionally makes positive displacement flow meters one of the more cost-effective options since they require no outside power supply to operate. However, these meters are ill-suited for impure fluids such as wastewater or slurries, as the suspended soils can clog or slow the reciprocating elements and create inaccurate readings.

    Electromagnetic Flow Meters

    Pros

    • Obstruction-less/No moving components
    • Highly accurate-unaffected by density, viscosity, turbulence, or pipe configuration
    • Can handle wide flow ranges & multiple fluid types
    • Zero pressure drop
    • Bi-directional
    • Cost-effective

    Cons

    • Cannot measure gases, vapors, or non-conductive liquids
    • Limited fluid temperature range
    • Interference possible with certain suspended fluids
    • Specialized subsets can be expensive

    Electromagnetic flow meters

     

    Electromagnetic flow meters, also known as magnetic flow meters or magmeters, are rather unique in the technology they use to measure flow. Magmeters feature two parts, a transmitter and an inline sensor, the latter of which features coils that generate a magnetic field. When a conductive fluid passes through the field, a voltage is produced proportional to flow. This flow principle is known as Faraday's Law.

     

     

    Unlike other meters, magnetic flow meters can measure fluids regardless of fluid density, viscosity, or flow turbulence. This makes mag meters highly accurate and reliable across a wide range of solutions. Additionally, their design features no obstructions in the pipe, making these meters ideal for a wide spectrum of applications, from highly sanitary liquids to slurries and highly corrosive fluids. Electromagnetic meters can be found in industries such as pulp and paper, metals and mining, food and beverage, water and wastewater, chemical transfer, and many more.

     

    Banjo Corp 3in Mag Meter



    Magnetic meters, however, only work with conductive fluids. This means hydrocarbons such as oils, gasoline, or deionized liquids are not recommended with mag meters. Suspended solids, such as those found in various ag chemicals and fertilizers, can also sometimes pose a problem. The suspended soils, which may not be conductive, can interrupt the magnetic field and throw off the reading's accuracy. Newer, specialized magmeters such as slurry magmeters are engineered to counteract this magnetic interference. However, these units generally feature heftier price tags compared to standard models.

    Turbine Flow Meters

    Pros

    • Highly accurate
    • Cost-effective
    • Capable of measuring low flow rates
    • Versatile applications-simple, reliable design

    Cons

    • Not recommended for dirty or suspended liquids
    • Require straight pipe runs for best results
    • Limited to certain pipe sizes
    • High flow rates can cause damage or inaccuracies
    • Moving components need regular maintenance and replacement

    Like paddlewheel or propeller flow meters, turbine meters feature a multi-bladed rotor mounted inline to fluid flow. Sensors attached to one or more of the turbine blades transmit the number of revolutions the turbine makes. The speed at which these revolutions happen is proportional to volumetric flow rate. Similar to positive displacement meters, turbine and paddlewheel meters only measure flow when fluid mechanically acts upon their metering components.

     

    Turbine Meter

     

    Because turbine meters provide accurate readouts in relation to linear flow-even at low flow rates-they are widely used in the oil and natural gas, custody transfer, and petrochemical industries. In fact, turbine meters are often used to help verify the accuracy of other meter types.

    Turbine meters aren't without their limitations, though. For starters, turbine meters are not well suited to handle dirty or highly viscous fluids, as the turbines can be easily fouled by the soils. These meters also require straight runs of pipe before and after the meter to stabilize flow for the most accurate results. Additionally, larger pipe diameters are incompatible from an engineering standpoint. This limits where and for what applications turbine meters can be installed. Finally, as with any technology with moving components, regular maintenance is necessary to keep these meters in peak-performing condition.

    Coriolis Flow Meters

    Pros

    • Extremely accurate
    • Low maintenance
    • Can handle a wide spectrum of flow ranges
    • Compatible with many dirty, corrosive & difficult to handle fluid types
    • Versatile installation-no straight pipe runs required
    • Serviceable without removing from the pipeline
    • Easy in-field calibration
    • Capable of measuring gases

    Cons

    • Expensive initial investment
    • Not suited for low-pressure gases
    • Limited to certain pipe sizes

    Coriolis meters, more commonly known as mass meters, differ from other meter types in that they measure mass flow instead of volume flow. These meters also feature a unique means of calculating flow rate based upon the Coriolis Principle. Check out the video below for a quick look at Coriolis meter technology.

     

    Advantages of Mass Meters

    Mass meters generally hold an NTEP certification and are widely used in legal-for-trade (resale) applications. In the Dultmeier Sales world, this generally means fertilizers or chemicals with respect to the agricultural industry. Back in the 1990s, Dultmeier Sales partnered with Kahler Automation to offer some of the first automated solutions for fertilizer/chemical plant automation.

    The mass meter was at the heart of the system because it was new technology that allowed end-users to sell using the real-time density of the product - a truer way to meter liquids. For example, water is known to be 8.34 lbs. per gallon at 70°F. However, as temperature drops, the weight of water increases. Thus, the solution of water becomes denser as the ambient temperature drops. This would mean static volumetric calculations would be off if one pumped 1000 gallons of water and converted to 834 lbs. (using 8.34lbs/gal as the constant conversion factor) if the water were only 50°F.

    This same principle happens with fertilizer and chemicals - as they are generally water-based solutions. Volumetric meters of the time; however, were unable to account for this change in density in relation to volume flow. Take this scenario for example, which was quite common in the 1990s and early 2000s:

    Let's say that it's 40° F. and we're loading a 10,000 gallon tender trailer, running 32% Nitrogen into the vessel. We're using a paddlewheel meter as our measuring device and pumping the product into the vessel. Once we reach our hit point of 10,000 gallons - the automated equipment shuts down and we send our trucker to the scale. The scale breaks in 20 lb. increments.

    Our potential for error:

    • Paddlewheel meter runs at approx. +/- 2% accuracy (mass meter is +/- .3% accuracy)
    • Paddlewheel cannot determine density reading, so we have a static calibration factor that was calibrated at 70° F. (or another temperature) and we are using that static factor to now calibrate pounds to gallons at 40° F.
    • Scale breaks in 20 lb. increments vs. mass meter measuring in increments of 1/10th of a pound
    • Scale cannot account for "slosh" or movement of liquid as truck stops abruptly on the scale

    Considering these many variables and the potential for error, it's no wonder why inventories could, and often would, be way off come year-end. We know that a solution's density changes constantly if in an ambient environment. For this reason alone, mass meter technology is the preferred method of measurement in many instances. By using a mass meter that can continually read this fluctuation in density on the fly, we offer our customers a better method to dispense and record inventory.

    Today, Dultmeier works with Easy Automation Inc. to provide automated plant solutions using mass meters in addition to other state-of-the-art meters, controls, and equipment.

    Flow Meter Price, Performance & Popularity

    Unfortunately, there is no universal flow meter that works for every application. Depending on how diversified your operation is, that could mean multiple types of flow meters are needed. While it is fair to research the most popular meters for your industry, don't buy the first meter you think will work.

    Price, quality, and other key factors do play a significant role in a flow meter's overall performance. Simply because everyone else uses a certain meter does not mean you should be. Low purchase cost, for instance, shouldn't be the deciding factor in choosing the best flow meter for your application. When choosing a flow meter, you have to consider not only the initial purchase price, but the overall lifetime costs and long-term returns on investment, too.

    Money investment scale.

     

    For instance, while a Coriolis meter boasts a hefty price tag at initial investment, it provides a great ROI because less maintenance and greater product savings are realized over the long run. Mass meters' exceptional accuracy, versatile flow ranges, and fluid compatibilities, minimal wearable parts, and the ability to recalibrate without removing the meter from the pipeline all translate to fewer dollars spent overall. When it comes to the bottom line, spending more money upfront can outweigh years of hemorrhaging dollars spent repairing or replacing inefficient meters.

    That said, not every operation needs an expensive, high-end flow meter. It's a good idea to run a cost assessment evaluating application needs against initial investment costs and long-term cost savings. This way you have the best picture of whether a certain meter is practical or worth the price tag over the long haul. If you need help assessing meter options and determining what is best for your application(s), we are always just a phone call away at 1-888-677-5054.

    Final Words

    We hope this article has provided some insight into the world of flow meter solutions. Although we covered some of the most common types, these are by no means the only flow meters out there. Choosing the best type of flow meter for your application all starts with knowing what you need and researching your best options. Compare all associated costs-both short and long-term-and avoid making a decision based on price tags alone. Ultimately; however, the manner in which you choose to meter is entirely up to you.

    If you have any questions regarding flowmeter selection, give us a call at 888-667-5054 or dultmeier.com. Dultmeier Sales carries a diverse inventory of chemical and water flow meters, flow meter repair parts, and flow meter accessories. No matter what meter your operation requires, our experience and technical expertise will help make sure you select the right one.

    (0) Disinfectant Basics - 3 Methods for More Effective Disinfecting

    20 Gallon Spill Kit

    We speak a lot about sanitation and disinfection these days. From the office and classroom to our own personal spaces, we are focused on cleaner, safer areas more than ever. And while many businesses are just now taking a closer look at how they clean their facilities, disinfecting in food processing has long been serious business. That doesn't mean all disinfectants for food processing cleaning are made equal.

    Disinfectants come in a variety of forms, each with its distinct advantages and disadvantages. In fact, which disinfectant you choose for your application is just as important as the why and how you disinfect. As we'll cover in this article, understanding the basics of each disinfectant type and the general rules behind applying them ensures a more comprehensive and cost-effective cleaning regimen. Read on for our breakdown of disinfection basics for more effective disinfecting.

    Why Disinfecting in Food Processing is So Important

    While commercial processing facilities spend the majority of their time up and running, their most important activity occurs when the production floor is empty and silent. Maintaining clean, sanitary workstations and equipment, particularly in food processing, is integral to public health and safety. In the United States, such standards are overseen by government agencies such as the EPA, CDC, and USDA.

    But why disinfect at all?

    E. coli, a common bacterial target of disinfecting food processing facilities

    E. coli, a common bacterial target of disinfecting food processing facilities



    Well, for starters, food processing plants are not the cleanest places once production gets going. Soils, in the form of fats, oils, blood, and other animal protein and production byproducts, quickly collect on equipment and surrounding surfaces. Such deposits, if left unaddressed, make these surface areas ideal breeding grounds for countless hosts of bacteria, viruses, and other potentially harmful microorganisms.

    Proper cleaning removes these unwanted soils and contaminants, providing significant benefits downstream. Maximized production efficiency, increased product shelf life, safer work conditions, and fewer mechanical failures and delays are but a few positive outcomes to attentive housekeeping. Scheduled cleaning and disinfection also significantly decrease the chances of costly product recalls due to food hazard risks such as food poisoning or foreign body contamination.

    A processing plant's commitment to a culture of health and food safety can easily be seen by how devoutly they approach the cleaning and disinfecting processes. And yes, there is a difference between the two.

    Cleaning vs. Disinfecting

    For most of us, cleaning, sanitizing, and disinfecting are all one and the same concept. They are, however, three distinct steps within the larger cleaning process. Cleaning is the process of physically removing unwanted substances and contaminants from a given surface. The cleaning stage, sometimes referred to as the detergent stage, is often characterized by the removal of common soils such as dirt, grease, or oils via manual scrubbing with brushes or wipes or washing with a high-pressure spray wand. Cleaning a surface in this manner alone; however, will not kill germs present.

    Tub-O-Towels - Heavy Duty Cleaning Wipes for removing difficult soils

    Heavy Duty Cleaning Wipes for removing difficult soils



    Disinfecting on the other hand, does kill bacteria and other microorganisms left behind following the cleaning stage. While similar to sanitizing agents, which merely reduce the number of bacteria and other germs to acceptable levels of health safety, surface disinfectants make a surface truly contaminant-free. Their high bactericide concentrations of chlorine or bleach eliminates the ideal growing conditions bacteria and other microorganisms thrive on.

    TACT Disinfection Cycle



    Every cleaning application will follow a distinct set of variables, generally known as TACT. The four aspects of this cleaning/disinfection concept are time, temperature, action, and concentration. How prominently each phase is in the disinfecting cycle depends specifically upon your unique needs, including the soils you're wanting to destroy, and the chemicals being used. Followed properly, the combination of them all will achieve the desired result of a clean, disinfected space.

    It's important to understand that cleaning must take place before the disinfecting stage. Since disinfectants do not break through heavy soils on surfaces, removing such deposits ahead of time ensures the disinfectants are able to work with the greatest efficacy.

    Choosing the Right Disinfectant for the Environment & Application

    Today, disinfectants cover a wide spectrum of chemical concentrations and applications. Choosing the right disinfectant for a specific environment, therefore, can be a task in and of itself. A few things to consider.

    First, the choice of disinfectants depends foremost on a user's requirements. In other words, where are they disinfecting and what type of contaminants are they trying to eliminate. After that, the type of processing and cleaning equipment used, the application method, and, to some degree, the personal preference of the user all play a role in selecting a disinfectant.

    Also, review a disinfectant's toxicity, leftover residues, and any possible chemical reactions related to water hardness and various surface types. This is particularly important within the food processing industry. Any residual chemical compounds left behind after disinfecting can adversely affect product taste, curing, and shelf life. In the brewing industry, for example, certain disinfectant cleaners are avoided because they linger on glass surfaces. (Soapy beer anyone?) Understanding a disinfectant's proper application process and any residue properties it has helps prevent product quality from suffering.

    Once a disinfectant is chosen, the most important thing to remember is to always read your disinfectant product labels! Always. With effective cleaning practices, disinfectants will kill 100% of germs listed by the label-when used properly.

    Disinfectant Label



    Ignoring what's detailed on the label-or choosing not to read it altogether-is a great way to undermine a disinfectant's effectiveness and cause mechanical failure of your disinfecting systems. It's also quite dangerous. Later in this article, we'll cover some of the safety considerations and equipment needed when dealing with disinfectants. For now, just remember that the label is the law. By following the label, you keep you, your cleaning staff, and anyone who comes in contact with the disinfected area, directly or indirectly, safe.

    Disinfectant Type Comparison: Foam, Spray & Steam

    Most of the food processing industry today relies on three common disinfectant application types: foam, spray (aerosol), and steam. Since no two environments are exactly alike, no two disinfectants will perform equally across the board either. Below we've provided some comparisons for these three disinfectant types and some general considerations to have before choosing the right disinfectant for your situation.

    Foam Disinfectants

    Foam Disinfectants



    Pros:

    • Better coverage of surfaces
    • Greater visibility of coverage
    • Lower pressure application
    • Less product needed to work
    • More cost-effective than other disinfectants

    Cons:

    • More challenging mix ratios
    • Added costs if needing separate surfactant agent
    • Greater attention to spray nozzle orifice size
    • Greater flow needed to apply

    Foam disinfectants are quite common in most food processing and industrial operations. Why? For starters, foam disinfectants can offer up to 50% more coverage than sprays. This is because foam expands as it comes in contact with a surface, greatly increasing coverage and disinfecting performance. In large production spaces, such as production floors or livestock barns, this helps keep cleaning costs down. Users can realize up to 50% cost savings on chemical alone, with additional savings possible in application time as well. Foaming is also a great option for disinfecting ceilings and vertical surfaces since the foam adheres better than sprays and therefore extends disinfection dwell time.

    One challenge with foam disinfectants, however, is the need to include a surfactant. A surfactant is a foaming agent that chemically reacts with your disinfectant chemicals. Surfactants also lower the surface tension between two materials, such as water and dirt, making the soil easier to remove. Without a surfactant, your disinfecting solution will not foam properly, making it less effective. While some disinfectants include a surfactant already, most do not. Be sure to read your labels prior to starting your cleaning process to ensure proper solution effectiveness.

    Additionally, check that your application equipment is compatible with foam solutions. Using a high-pressure pump without the appropriate chemically compatible elastomers is a great way to ruin an expensive pump. It is imperative, therefore, to check the chemical compatibility of ALL components throughout your entire cleaning systems. That includes examining the largest pump to the tiniest o-ring. In doing so, you not only avoid costly equipment damages or failures, but also prevent ineffective treatment from taking place.

    Hydro Systems FoamMaster



    Opt for chemical spray foamers and accessories that feature downstream injectors that bypass incompatible seals and components. Better still, invest in a complete foaming system like the Hydro FoamMaster. Available in multiple mounting styles, the FoamMaster is ideal for larger industrial cleaning applications, from washdown facilities and meatpacking plants to animal production buildings, such as the dairy barns shown in the video above. These compressed air units allow a user to set the desired dilution rate for their specific application. From there, the system mixes the chemical and surfactant with the carrier agent (generally water) to create rich, clinging foam.

    Dultmeier has even helped develop custom disinfecting systems. Check out our work on the JBI Poultry Disinfectant Foaming Trailer here.

    Spray Disinfectants

    User disinfecting with spray in an industrial kitchen

    User disinfecting with spray in an industrial kitchen



    Pros:

    • Fewer chemical compatibility issues
    • Quick-and-easy to apply
    • Wide variety of disinfectant types
    • Usable for almost any application/environment

    Cons:

    • More chemical usage to achieve adequate coverage
    • Generally higher pressures applications
    • Greater health concerns due to aerosol emissions

    Dultmeier Sales DC1 Air-Driven Disinfectant Applicator

    Dultmeier's DC1 Air-Driven Disinfectant Applicator



    Aerosols are the most widely used disinfectants used for industrial cleaning tanks to their incredible versatility and ease-of-application. You can find disinfectant sprays for nearly every circumstance and apply them using a commercial pressure washer, handheld or backpack sprayer, or similar system without any chemical compatibility issues. Dultmeier's DC1 disinfectant applicator system, for instance, features an air-powered diaphragm pump, a 25 gallon storage tank with an automatic mixing valve, and a trigger spray wand that can easily store and apply most disinfectant products without a problem.

    Complete Plant Washdown/Industrial Clean System

    Complete Plant Washdown/Industrial Clean System



    The thing about spray disinfectants is that they can be costly. For one, most disinfectant sprays require a high-pressure system to be applied well. These systems; while effective, can be expensive to fund. Furthermore, since so much energy goes into turning a disinfecting solution into spray, an operator may have to use more product to disinfect an area compared to if he used foam.

    Steam Disinfectants

    Dry steam disinfecting for food processing sanitation

    Dry steam disinfecting for food processing sanitation



    Pros:

    • Effective against a wide range of microorganisms
    • Not affected by soils or hard water
    • Non-corrosive or chemically reactive
    • Leaves behind zero residue

    Cons:

    • Cannot be used on heat-sensitive equipment or surfaces
    • Does not remove large soil deposits
    • Dangerous high temperatures to human contact
    • Difficult to maintain consistent temperature and exposure

    As their name suggests, steam disinfectants work using steam to kill bacteria, spores, and other contaminants. The prolonged exposure to the moist high heat destroys microorganisms, leaving surfaces truly decontaminated.

    Although a viable disinfectant method, we recommend using either foam or spray detergents for most applications. The main drawback to steam is that high temperatures, generally either 250° F or 270° F (or greater), must be maintained throughout the disinfection process to ensure microbial death. Such high temperatures can also damage certain components and surfaces. Foams and sprays have much wider applications, which simply makes them better and more-cost effective options for most operations.

    Disinfecting Scope - Know Before You Go

    No two areas are created equal when it comes to cleaning and disinfecting. Case in point, you don't clean and disinfect an office space in the same way you do a meat packing processing floor. That makes understanding your scope of disinfection all the more important before ever beginning the cleaning process.

    Product Needs

    Pure hard surface disinfectant

    Purehard surface disinfectant; ideal for food processing & food preparation



    For instance, the size of the area you're disinfecting will greatly influence the amount of product needed. Do you need a 5-gallon bucket of disinfectant or a 55-gallon drum? Maybe you need more. This is where foam disinfectants really have the advantage. Their enhanced coverage and prolonged contact time with the applied surface allow less product usage.

    Make note of the GPM flow of your system. If you have a pump that produces 3 GPM of flow attached to a 50 gallon tank, you effectively have 16.5 minutes of continuous application time. Time is money, so how much time will be spent mixing solution is an extremely important thing to remember when disinfecting large areas.

    Disinfectant Systems

    Your style of disinfectant system is something else to keep in mind. Most operations have some level of clean-in-place (CIP) process. However; for a vast majority of the disinfecting process, mobile cleaning units are necessary to leave an area truly decontaminated. Portable disinfectant systems equipped with powerful pumps and spray wands allow an operator to spray disinfectant at a variety of angles, speeds, and tailored quantities. This versatility ensures every hard-to-clean space can be adequately decontaminated.

    Portable Sani-Mister disinfectant unit

    Portable Sani-Mister disinfectant unit



    Ventilation

    Finally, take a minute to evaluate your space's ventilation. Taking the office vs. processing floor scenario, ventilation is likely very different between the two spaces. On the processing floor, the larger area means aerosols and vapors have more room to dissipate or be dispersed by exhaust fans. In the smaller office space, however, chemical fumes become more of a hazard. Respirator masks may be required based upon the chemicals used and/or size and ventilation capabilities of the application area.

    Always be cognizant of how to enter a space for disinfection and understand how your solutions react when in use. Evaluating how to approach an enclosed space for disinfecting and how long someone should be exposed to that environment once they start keeps everyone healthy and safe.

    Safety First: Personal Protective Equipment (PPE) for Disinfecting

    Personal Protective Equipment PPE for Disinfecting



    Regardless of the style of disinfecting you ultimately use, you need to wear personal protective equipment, also known as PPE. This protective equipment ranges from nitrile chemical gloves and safety goggles to full body TYVEK coveralls. These products protect you from spills, splashes, and unexpected contact with the disinfectants which can cause serious chemical burns.

    Reusable Unlined Gloves



    Certain aerosol disinfectants may even require a respirator mask to protect you from harmful chemical vapors. Even if the disinfectant label doesn't list a respirator as required PPE, you may still choose to wear one if working in a small, poorly ventilated space. Each chemical application is different.

    Read your product labels for the proper PPE required to handle specific disinfectants safely. Regularly inspect PPE for wear or damages and replace if needed. Also, ensure your facility has clearly marked eyewash stations and safety showers in case of an emergency. Whether you need gloves, eye protection, or water-resistant clothing, we can help you find the gear you need to be best equipped for the tasks at hand.

    Conclusion

    Proper cleaning and disinfecting procedures will always be a serious focus in the industrial and food processing industries. In fact, one of the most important activities that occurs in any industrial processing facility is their disinfectant regimen. Even so, disinfection practices and policies will continue to change with new health research, product development, and societal perceptions. With that in mind, having a reliable, knowledgeable company you can trust to support you is imperative to your business's success.

    Dultmeier is that company you can trust. We carry an extensive catalog of disinfectants, personal protective gear, and cleaning equipment and supplies from trusted brands like Mosmatic, DEMA, Suttner, General Pump, Hydro Systems, Boss, and others. While we cannot ultimately tell you how to disinfect, we can share with you the many different methods and assist your operation regardless of your choice of application. We'll happily help answer all your questions about various disinfecting types and work to get you the equipment and products you need to ensure your workspaces are cleaner than ever.

    Reach us at dultmeier.com or give us a call at 888-667-5054. Your Experts in Delivering Fluid Handling Solutions - WE KNOW FLOW!

    (0) A New Age of Spraying – How To Size PWM Spray Nozzles

    The commercial spraying industry continues to improve technology. At this point, incremental gains can make a tremendous impact and that incremental gain can be as smaller than a 60 micron droplet. If you have a new spray rig, you're probably not alone. Favorable grain prices paired with government payouts related to COVID-19 have allowed many operations to afford asset upgrades this past year. Maybe that asset upgrade came with Pulse Width Modulation technology? If so, this post is a must read for you prior to sizing your spray nozzles this season.

    Speak at length with anyone involved in the ag sprayer industry about the new advances in sprayer technology, and there is a solid chance you'll hear the phrase "pulse-width modulation" mentioned. Although the technology isn't exactly new, advancements in spray nozzle design and overall efficiency of pulse-width modulation (PWM) spray systems arrive on the market every year, along with a slew of new PWM spray nozzles.

    Following up on our article on sprayer nozzle sizing, we'll focus on explaining how PWM systems work and provide you example-based guidance for how to size a PWM spray nozzle on your own. We'll also explore the benefits of PWM spraying and why it may be time to consider making the switch from a conventional sprayer system to one outfitted with PWM spray nozzles and accessory components. Read on for all the details and be sure to use the table of contents to help you get around.

    Pulse-width Modulation Explained

    Pulse-width modulation was first developed for the agriculture industry in the 1990s by Dr. Ken Giles, a professor of Biological and Agricultural Engineering at the University of California, Davis, and Capstan Ag Systems. For many farmers and agronomists today, however, pulse-width modulation still presents considerable degrees of uncertainty and understanding. So, let's clear up the confusion.

    Pulse-width modulation, in ag-related terms, refers to how liquid flow rates are controlled via an electronic signal and shut off valve. Unlike conventional sprayer booms, a PWM system features nozzle bodies each equipped with an electric solenoid. As this solenoid turns on and off-typically an average of 10 times a second-an intermittent, pulsed spray is created through the nozzle. The proportion of time that the solenoid is open is known as the pulse width or duty cycle. It's this percentage of time the nozzle is open vs. closed that ultimately dictates your rate of application.

    PWM solenoid actuated nozzle body.

    Cross-section illustration of a PWM solenoid-actuated nozzle body.



    Because duty cycle plays such a significant role in determining proper sprayer calibration for PWM operation and PWM nozzle sizing, it's best we dive a little deeper into how this concept works. That way, you will know exactly how to choose the proper size spray nozzle for your specific agricultural operation.

    Duty Cycle - The Driving Force Behind PWM

    One of the limitations of conventional sprayer systems is that nozzle flow varies indirectly with sprayer pressure. As the sprayer speeds up, the system must adjust pressure to also adjust flow rate to deliver the same application rate per acre. Generally, a device called a rate controller automatically recalculates the necessary adjustments for you. So, when the sprayer increases speed, the rate controller causes spray pressure to increase as well until the flow rate sensor shows that the nozzle flow is enough to maintain the target application rate desired.

    There are two related problems with these conventional spray systems. First, pressure must be increased significantly in order to increase flow rate as speed is increased. For instance, nozzle pressure must be doubled for nozzle flow to increase by just 41%. Moreover, pressure must be tripled to increase flow by 73%. Most sprayer pumps cannot achieve this doubling or tripling of their output while increasing flowrate.

    Secondly, sprayer tips are very sensitive to changes in spray pressure. Go too slow and the lower pressure can cause the spray pattern to collapse. The result is poor, inconsistent coverage. Drive too fast, though, and your droplet size becomes finer, creating drift problems. This delicate balance means traditional sprayers must remain within a very specific, narrow speed range, which is not always possible given field conditions or with variable rate applications.

    A key aspect in PWM systems is that spray nozzle output is no longer tied solely to sprayer pressure. Instead, PWM systems focus on duty cycle. Again, duty cycle is the proportion of time that the solenoid is open/on, meaning the percentage of time that your spray nozzles are actually spraying.

    PWM Duty Cycles

     

    Typical duty cycle ranges are between 20-100%. Although lower duty cycles are possible, they are not recommended since droplet size and spray pattern can become inconsistent.

    During operation, every nozzle can spray at its maximum flow (100% duty cycle) or a fraction of its flow capability. That means a nozzle operating at a 20% duty cycle will deliver about one-fifth of the flow of a spray nozzle spraying 100% of the time. Even so, the pulses occur so quickly that spray pattern and droplet size won't be adversely affected.

     

    What does this mean in practice? For one, while duty cycle is still linked to changes in sprayer speed, the spray pressure remains constant. This enables a sprayer operator to make pressure adjustments to maximize coverage or drift control independent of speed and the rate of application. The end result is a spray application that is not only more accurate but also more consistent across diverse field conditions.

    Calculating Duty Cycle

    Duty cycle directly correlates to ground speed. When calculating duty cycle to correctly size your PWM spray nozzles, you want to aim for an average speed around 75% duty cycle. For example, if you figure you'll travel between 10 and 20 MPH while spraying, you'll want to choose your spray nozzle for an average speed of 15 MPH-or 75% of your maximum speed. This gives you plenty of flexibility to adjust the duty cycle up or down if you experience unexpected changes in speed without compromising your droplet size or spray pattern integrity.

    Selecting the Appropriate Spray Nozzle for PWM Systems

    Since the means of controlling nozzle flow rate is different between traditional sprayer setups and those with pulse-modulation, sizing PWM nozzles likewise differs a bit from conventional spray tips. This means that you won't necessarily be able to use traditional flow rate tabulation charts to size your nozzles. No need to fear, though. The PWM spray nozzle sizing process is still easy to understand.

    There are three things to remember when selecting PWM nozzles. For starters, you want to always choose wider angle spray nozzles for pulse-width systems. One of the biggest concerns regarding PWM spraying is the risk of application "skips" as you move through the field. Wider angle nozzles such as 110° flat fans ensure you'll produce enough overlap in your spray coverage to eliminate skipping.

    Additionally, you'll want to avoid using air-inducted spray nozzles for PWM spraying. The introduction of air can compromise the spray pattern and droplet size as the nozzle pulses off and on. As shown in the video below (at 3:18), this deterioration of droplet size is especially obvious upon the valve pulsing off, where residual air causes the application to dribble out from the air inlets-thus rendering the spray nozzle ineffective.

    Now, new advancements have been made regarding air-induced nozzles regarding pulse-width modulation. TeeJet, for example, has several air-induced nozzles that have been approved for PWM use. However, your best bet is still to use non-air-inducted nozzles such as the Turbo TeeJet and Turbo TwinJet. The Greenleaf Soft Drop or Blended Pulse Dual Fan (BPDF) series or Wilger ComboJet series are good options, too.

    Finally, an important point to remember when using PWM systems is that nozzle pressure is different than boom pressure. This is because nozzle pressure/flow is now controlled by the solenoids which are independent of your overall system's pressure reading. As the solenoids turn off and on, a pressure drop needs to be accounted for with higher boom pressure.

    Difference between gauge pressure and nozzle pressure for an 0.8 nozzle.

    Difference between gauge pressure and nozzle pressure for an 0.8 nozzle.



    For example, for a 110-04 spray tip, the average drop is only about 3 PSI. A larger 110-08 tip, however, will push the limits of the solenoid even further, creating a greater decrease in pressure. This can be anywhere from 6 PSI at 30 PSI gauge pressure to 13 PSI at 60 PSI gauge pressure! If the pressure drops too low, the nozzle won't be able to form a uniform spray pattern and droplet size. Therefore, the larger the nozzle orifice, the greater the boom pressure required to compensate.

    PWM charts calculate against this pressure drop and offer speed ranges for operating specific nozzles at a given gauge pressure.

    Sizing PWM Sprayer Nozzles

    Alright, let's size some spray nozzles. A few things you'll need to know ahead of time:

    • Target application rate
    • Typical average speed
    • Desired droplet size

    Using these three components, you'll be able to quickly find the correct spray nozzle size for your PWM application.

    Once you start looking at the charts, just like with conventional spray tips, you want to select a PWM nozzle which falls near the center of the pressure range for your desired droplet size. In most cases, this will be between 40 and 70 PSI for the best pattern and droplet size retention. However, it's difficult to suggest the proper droplet size and nozzle type for every application. As always, check your chemical labels for proper application droplet size before beginning.

    Sizing Greenleaf PWM Nozzles

    For this first example, we're going to find a nozzle within the Greenleaf line of spray nozzles using their PWM tabulation chart. To start, we take our target application rate, let's say 12.5 GPA on 20" spacing, and set our average speed at 15 MPH. Keep in mind we want to maintain a 75% duty cycle through the field. This means we can go as fast as 20 MPH (100%) or as slow as 5 MPH (25%) without exceeding our chosen nozzle's pressure rating or compromising our droplet size or application rate. Our droplet size for this example is Coarse to Very Coarse.

     

    Next, moving down the 75% duty cycle column, we find where our average speed of 15 MPH falls within the 40 to 60 PSI gauge pressure range. Looking left, we see that the best fit is a 0.8 nozzle. We can also readily see that only one nozzle, the BPDF, will provide our desired droplet size.

     

    We could've chosen an 0.7 nozzle, but we're already pushing the pressure limits of that nozzle at our speed. If our average speed was to increase by even one mile to 16 MPH, our droplet size would decrease to Medium. Choosing an 0.8 nozzle still retains our Course-Very Course droplet size even if we were to decrease pressure or speed.

    Sizing TeeJet PWM Nozzles

    TeeJet has a similar approach to sizing PWM nozzles, though their tabulation chart works a bit differently. Instead of providing you with the duty cycle columns, they simply display your minimum/maximum speed range. This means you have to calculate what the 75% duty cycle speed would be on your own. Once you have that however, you can quickly find your ideal spray nozzle.

     

    In the example below, we chose to apply a 15 GPA at 10 MPH with a desired Ultra Coarse or Extremely Course droplet size. We actually have two nozzle options to choose from in this case-the Turbo TeeJet Induction (TTI) and TTI TwinJet (TTI60). Both are again in the 0.8 size.

     

    We also have the Air-Inducted Turbo TwinJet (green box) with an XC droplet size if we wanted. However, the larger UC droplet size of the other two nozzles and the fact that they aren't air induction nozzles makes them better options.

    Sizing Wilger PWM Nozzles Using the Wilger Tip Wizard

    Wilger has made selecting their Combo-Jet nozzles for PWM systems even easier via their online Tip Wizard. Here, simply enter your GPA, speed, and target droplet size into the specific fields. You'll also enter nozzle spacing, spray tip angle, and which PWM system you're operating on. Many PWM systems, from Capstan PinPoint to Case AimCommand, Raven Hawkeye to John Deere ExactApply have different actuation speeds. The Tip Wizard will then provide you a list of the best nozzle options given your specifications.

     

    For a complete guide to using Wilger's Tip Wizard and understanding results when sizing nozzles for PWM, click here. They even have a video walkthrough if you prefer that option.

    Advantages of Using Pulse Width Modulation Nozzles

    Although there is no indication that conventional spray nozzles will become obsolete in the near future, the rise of PWM nozzles will undoubtedly continue to assume an increasing share of the industry. And for good reason.

    First, PWM spray nozzles allow you to maintain constant pressure across a wide range of speeds. Having a wider range of travel speeds means that even when speeding up or slowing down through the field, you retain the necessary pressure-and therefore droplet size-to correctly apply your desired chemical rate without sacrificing coverage.

    Drift control is another benefit of using PWM nozzles. While PWM systems do not significantly improve drift control alone, they do make it easier. This is because they offer a wider speed range to work with, meaning you can use larger sprayer nozzles designed for coarser spray patterns. Even if you tweaked your pressure higher or lower, your duty cycle would internally adjust to apply the same application regardless of speed. The larger droplet sizes then allow you optimal drift control.

    Illustration of turn application rates for conventional spray system with rate controller

    Illustration of turn application rates for conventional spray system with rate controller only (left) vs. a PWM system with nozzle-by-nozzle turn compensation capability (right)



    Finally, greater precision. The consistency across numerous speeds means PWM spray nozzles provide incredible application accuracy. Reduction in chemical costs, fewer over- or underapplications, and less drift potential gives PWM operators much more control over their spray operation. Many systems today even have the capability of controlling individual nozzle flows. This nozzle-by-nozzle sectional control enables greater turn compensation and more accurate, site-specific application through the field.

    This feature is especially important when turning around at the end of the row. When turning in a conventional sprayer system, the inner boom nozzles become effectively stationary and substantially over apply chemical. Meanwhile, the outside boom nozzles move faster than the application rate can be accurately applied. PWM systems featuring turn compensation such as Capstan's PinPoint overcome this by individually controlling each nozzle, maximizing efficiency and accuracy.

    Final Thoughts

    As industry leaders continue developing new, better PWM spray equipment systems, understanding PWM technology and how to apply it to your own operation becomes increasingly important. Not unlike sizing conventional sprayer tips, choosing the correct PWM spray nozzle plays an integral role in ensuring the accuracy and efficiency of your sprayer system. After all, your application is only as good as your spray tip.

    For any questions regarding sprayer tip sizing and PWM spray systems, be sure to check us out at dultmeier.com or give us a call at 888-667-5054. We're happy to assist you with whatever questions you may have and provide you the technical expertise and diverse products necessary to get you back in the field. Let us help you find what you're after today so that you get the best sprayer performance possible.

    Your Experts in Delivering Fluid Handling Solutions - WE KNOW FLOW!

    Sprayer Nozzle Sizing — How To Properly Size Spray Nozzles

    Whether it's 1980 or 2021 - Dultmeier Sales fields thousands of calls each spring on this topic alone. How do I size my spray nozzles? We don't help you select the type of spray tip for your application(s) - we advise you to consult your agronomist in this instance so they can get eyes on the crop situation to help develop a custom plan for your operation. That being said, once you've identified which type of nozzle(s) you need, we can absolutely assist in the sizing of said nozzles. This post is a great resource to use that helps to outline what we do just about every day during spring.

    It's spring, and with the frenzy of field preparation, fertilizing, and putting seed in the ground on everyone's mind, the height of the planting season is nearly upon us. This time of the year also signals, if you haven't started already, that the time for you to begin readying your sprayer for your early season spraying is fast approaching.

    Between calibrating your sprayer pump and checking all your hoses, you already have a lot to get done in order for your sprayer to be ready for the field. One of the most important parts of your sprayer prep; however, is ensuring that you have the correct sprayer nozzles appropriately sized for the chemical and fertilizer solutions you're looking to apply.

    Without serious attention to detail, improper nozzle sizing can lead to a multitude of mistakes and delays when you can least afford them, not to mention the increased costs. In this article, we'll examine the proper approaches for how to size nozzles for various spray application types and how to attain ideal nozzle coverage and drift control. We'll also share why correct sprayer nozzle sizing is so important to your sprayer and crop performance. Read on at your leisure or use our table of contents to help you navigate through the article to find the answers you're looking for.

    Nozzle Sizing Information to Know Before You Begin

    Sprayer nozzle sizing can often be a confusing bit of business, especially with new tips and nozzles being designed every season. Pulse width modulation anyone? Luckily, the way you decide which nozzles you need has remained essentially the same for years. The first step is ensuring you have three pieces of critical information:

    • Rate of application - in gallons per acre (GPA)
    • Average sprayer speed ­­- in miles per hour (MPH)
    • Nozzle spacing - in inches (W)

    Once you have those pieces of information nailed down, you can then plug them into a standardized formula and calculate how many gallons per minute (GPM) that you need to apply. Here's the formula:


    GPA x MPH x W / 5,940 = GPM (per nozzle)


    Knowing the number of gallons per minute you need to spray then allows you to reference a sprayer nozzle sizing chart that you can use to locate the ideal nozzle size for your specific sprayer setup. There are also plenty of tip sizing tools available online that calculate the best tip size for you. You can try our GPM calculator or use these from the nozzle manufacturers:

    In the next section, we'll put this formula into practice and walk you through a few examples of how to size your sprayer nozzles for different chemical and fertilizer applications so you have a better idea of how to approach it on your own.

    Sprayer Nozzle Sizing for Different Applications

    Although sizing spray nozzles is largely uniform across the board, there are a few slight differences in how to size a sprayer tip depending on the type of liquid solution you're applying. Here, we've included the two most common application types when sizing broadcast nozzles: chemical/water solutions and liquids heavier than water.

    Sizing for Ag Chemicals and Water Solutions

    A vast majority of your sprayer applications will fall under this category since it includes most of your herbicides, insecticides, fungicides, and other common ag chemicals. Sizing nozzles for this type of application is also the most straightforward since you're using water as the base agent and aren't having to adjust for a higher relative density.

    Relative density, also commonly referred to as specific gravity (SG), is the ratio of density-or mass of a unit volume-of a substance to the density of a standard reference material. For liquids, specific gravity is almost always measured against water since water has a specific gravity of 1.0. When calculating the application rate of liquids heavier than water, you must use a conversion factor to compensate for the higher solution density. We'll cover more on these conversion factors when we discuss sizing sprayer nozzles for liquids heavier than water a bit later. For now, though, assume that our examples are calculated with the SG of water.

    Now, many sprayer nozzle sizing charts will display a wide selection of common spraying speeds. If your speed is already in the table, simply cross-reference your nozzle spacing and speed and locate the GPA you want to apply. But what if the speed you want to spray at isn't shown on the table? This is where the formula plays such an important role.


    Shows how to find nozzle size for 8 GPA at 6 MPH for 20

    Shows how to find nozzle size for 8 GPA at 6 MPH for 20" nozzle spacing when all information is listed in the chart.

     


    So, example time.

    Let's say we want to spray 20 gallons per acre of 2,4-D. Our average sprayer speed in the field is 12 miles per hour (not shown in the table), and we are operating on 20-inch nozzle spacing. Our formula would look something like this:


    20 x 12 x 20 / 5940 = 0.808 GPM (per nozzle)


    Let's also say that we want a course droplet size and are looking to use a Turbo Teejet wide-angle spray tip. Taking our 0.808 gallons per nozzle rate and using the Teejet sizing chart for this model of spray tip, we scroll down the Capacity in One Nozzle column to the nozzle size most closely matching our desired specifications. In this example, that would be the white tip nozzle.

    Nozzle Capacity Chart

     


    It's best practice to find a nozzle that meets the GPM rate as close to the middle of the PSI range as possible. This is important in relation to your speed. Most spraying systems rely on largely consistent speeds across the entire field for the optimal performance. As a result, slow down too much, such as at the end rows, and you compromise your spray pattern and improperly apply your chemicals. Go too fast, and your sprayer pump may not be able to match your new pressure rate for the nozzles you have, setting off system alarms.

    Even if your sprayer pump can match the higher speed, your droplet size then becomes much smaller, increasing your risk of drift. Neither case is what you want. Having a spray nozzle in the middle of the range ensures that you're able to maintain spray pattern, solution density, and droplet size-even with slight rises and drops in speed.

    Sizing for Ag Liquids Heavier Than Water

    When sizing your spray nozzles for liquid solutions heavier than water, such as liquid fertilizer, you'll follow a very similar process as sizing nozzles for your water-based ag chemicals. The difference in sizing for this type of application; however, is that you need to adjust for the higher density of your solution. You accomplish this by using a density conversion factor seen in the chart below.


     


    So, let's say we wanted to apply some liquid nitrogen fertilizer. Using the conversion chart above with our previous example, our formula would look like this:


    20 GPA x 12 MPH x 20 W / 5940 = (0.808 x 1.13 Con. ) = 0.91 GPM


    In this case, you'd still use the white nozzle tip from our previous example since the 0.91 GPM still falls near the middle of the pressure range for the course droplet size desired. If your speed is shown in the chart, simply take your intended GPA multiplied by your conversion factor to locate your nozzle size.

    The key in either case is to factor in the conversion factor before you reference the sizing chart. Otherwise, you'll select the wrong spray nozzle and wind up with improper droplet size and inaccurate application. In the next sections we'll examine why these two ideas, spray coverage and droplet size, are tied so closely to the idea of proper nozzle sizing.

    Nozzle Spacing and Spray Heights for Proper Coverage and Overlap

    It should come as no surprise that sizing your spray tips correctly is just as important as where you put them on your sprayer. In fact, nozzle spacing and sprayer boom height are two aspects you mustn't ignore when choosing the size of the spray tip that you need.

    For starters, nozzle placement-both width between nozzles on the boom and the height of the nozzles above the ground-determines how well your spray coverage theoretically performs based upon the fan angle a nozzle has. Most setups will use some type of nozzle which creates a fan-shaped spray pattern. This means that the heaviest concentration of spray is at its center and tapers off to nothing at the edges. Common sprayer systems operate on 20, 30, or 40-inch nozzle spacing, and the arrangement of nozzles at these spacings determines how uniformly your application is ultimately applied.

    To achieve uniform application; however, you'll need to create a pattern overlap in your spray coverage. Overlap-or the combining of spray patterns-is necessary, particularly in broadcast spraying, because the outer edges of spray patterns don't have uniform volume distribution. Without overlapping coverage, you risk leaving portions of your field under-treated or even skipped. That means you'll likely spend more time and money correcting the mistake.


    Illustration of spray pattern overlap.

    Illustration of spray pattern overlap.

     


    Factors that affect spray nozzle overlap

    Three factors affect overlap in relation to sprayer nozzle sizing. First of all, your nozzle fan angle determines the total width of the spray pattern. The wider the fan angle, the wider the spray pattern. Today, 80-degree and 110-degree fan angles are the most used nozzle angles in agriculture applications, though others are available. Second, spray tip spacing. The closer the nozzles are to one another, the more the patterns will overlap. Farther apart, and the amount of overlap is lessened.

    Finally, adjusting your spray tip height will further affect how much overlap you have. The higher the boom, the more overlapping because each pattern has more room to spread out. Another good thing to remember regarding the height of your spray tips is that the higher above the row your boom/tips are, the more susceptible to wind and drift your solutions are. We'll touch on this a bit more in relation to droplet sizing in the next section, but for now keep it in mind.

    Now, unsurprisingly, not all spray nozzles are the same. Finding the proper height in relation to your nozzle spacing then is imperative. In the table below for example, you can see the height recommendations of various TeeJet nozzle series based upon nozzle fan angle and boom spacing.


    Suggested Minimum Spray Heights

     


    In most cases, your ideal overlap for broadcast spray nozzles is approximately 30%. Adjusting your nozzle spacing and boom height accordingly will give you the best chance to maintain adequate, uniform coverage across the entirety of your system, even when other variables such as wind speed and pressure decreases occur.

    Maintaining Droplet Size for Optimal Drift Control

    Finally, we want to share a few words on droplet size. Namely, follow your labels.

    After all, the label is the law! Not following how a specific chemical or pesticide is meant to be applied can create serious damage to not only your crops, but your fellow farmers' as well. This has become especially important when dealing with volatile chemicals like Dicamba.


    Burn damage caused by Dicamba drift.

    Burn damage caused by Dicamba drift.

     


    Make sure that you've chosen and sized a sprayer nozzle capable of producing the appropriate droplet size recommended for the chemical you're applying. If the label lists a specific nozzle or droplet size to use, follow those listings to a T. Furthermore, install your spray tips at the proper boom height and operate at the required pressure range to achieve the stated recommended droplet size of a given chemical. This will significantly reduce the likelihood you experience issues with ‘hanging' droplets and drifting.

    Consulting the spray label is just smart practice. It can determine whether or not you need to make any additional adjustments to your spray equipment or need to purchase additional nozzle accessories to attain the right nozzle spacing and droplet size specifications.

    Importance of Proper Sprayer Nozzle Sizing

    We don't have to tell you that your time is money. When it's time for you to be spraying in the field, you can't afford troubleshooting on the fly or stopping to recalibrate your sprayer a second or third time.

    Which is the exact reason why you should take the time well in advance of spraying season to research the agricultural chemicals and fertilizers you intend to apply. Running long or short of chemical means your solutions were not applied efficiently and may not work as effectively as intended.

    In fact, overapplication due to poorly sized or worn out sprayer nozzles is a serious problem if left unaddressed. Ag chemicals are very expensive, and if you're over applying it, you're wasting money. All the major manufacturers that we represent recommend replacing any spray tip if it's overapplying by 10% of the rate of a new nozzle. That includes TeeJet and Hypro to Wilger, Greenleaf, and Delavan.

    If you find that at least two of your nozzles are overapplying by this rate anywhere across your boom, replace every nozzle in the system. Using a sprayer nozzle calibration tool, like the one shown below, will give you the fastest and most accurate reading of how your nozzles are performing and if you need to swap them out for new ones.


    SpotOn Electronic Sprayer Calibrator, 0-1.0 GPM

    SpotOn Electronic Sprayer Calibrator, 0-1.0 GPM


    Incorrect spray tip sizing has ramifications on your other sprayer components as well. Your sprayer pump especially may struggle to operate at its ideal performance. This can substantially increase the wear and tear on your pump components and lead to an inability of your pump to create or hold the spray patterns and proper application density.

    Conversely, your pump outperforming your spray nozzles at higher speeds can change the droplet size. Higher pressures create smaller droplet particles and lead to increased risk of drifting that can cause serious damage to you or your neighbor's crops when dealing with many of the volatile chemicals used today. Be sure to routinely examine your sprayer tips for wear of the nozzle orifice for the reason that you ensure they aren't in need of replacement in order to maintain the correct droplet size you're after.

    In the end, understanding how your agriculture chemicals and fertilizers are meant to be used and their proper droplet size ensures both appropriate solution application and adequate drift prevention. Once you have that information, the rest is relatively easy.

    Conclusion

    Although the science behind sizing sprayer nozzles has become more dynamic in recent years, the process doesn't have to be complicated for you. Following the guidelines in this article will give you a great start to your spraying season and ensure you aren't left reworking your sprayer when you should be in the field.

    Be sure to check us out at dultmeier.com or give us a call if you have additional questions regarding sprayer nozzle sizing. We offer a huge selection of TeeJet, Hypro, Greenleaf, Wilger and Delavan spray nozzles to suit your unique sprayer setups. Our team of experts will be glad to assist you with any concerns or questions you may have and discuss how to ensure you're getting the best performance from your spray nozzles.

    After all, we're your Experts in Delivering Fluid Handling Solutions - WE KNOW FLOW! ®